Figure 2. Differential Lock Air Supply Components.
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is Released Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  631    632    633    634    635  636  637    638    639    640    641  
img
.
TM 5-3805-296-23-2
0111
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is
Released Continued.
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Machine Cannot Make
6. Pivot cover (Figure 3, Item 4).
Quick Release Valve Damaged
Complete Left or Right Turn
Inspect differential lock air supply
Replace quick release valve
After Differential Lock is
hose (Figure 3, Item 1), quick
(WP 0269).
Released Continued
release valve (Figure 3, Item 2),
Proceed to Test Step 6.
and hose (Figure 3, Item 3) for
Hose(s) Restricted or Damaged
leaks, restrictions, and damage
Repair or replace as necessary
(WP 0280 and WP 0269).
(WP 0280).
Proceed to Test Step 6.
No Problem Found Proceed to Test
Step 3.
Figure 3. Differential Lock Air Supply Components.
0111
Test Step 3. Test Voltage to
Differential Lock Solenoid.
1. Disconnect connector W-C24
(WP 0012, Figure 63) from
differential lock solenoid connector
(WP 0012, Figure 62).
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. Using digital multimeter (WP 0540)
Voltage Present Proceed to Test
to test for voltage between
Step 4.
connector W-C24 terminal 1
No Voltage Present Proceed to Test
(WP 0012, Figure 63) and ground.
Step 5.
0111-5