Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is Released Continued.
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is Released Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  635    636    637    638    639  640  641    642    643    644    645  
img
.
TM 5-3805-296-23-2
0111
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is
Released Continued.
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Machine Cannot Make
6. View pressure reading on gauge
Gauge Reads Zero Air Pressure
Complete Left or Right Turn
(Figure 5, Item 2).
Proceed to step 7.
After Differential Lock is
Gauge Reads Air Pressure
Released Continued
Remove test hose and gauge from
hose and connect hose on fitting.
Replace differential lock solenoid
(WP 0271).
Proceed to Test Step 6.
Figure 5. Assembling Test Gauge and Hose.