Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is Released Continued.
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is Released Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  633    634    635    636    637  638  639    640    641    642    643  
img
.
TM 5-3805-296-23-2
0111
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is
Released Continued.
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Machine Cannot Make
Test Step 5. Test Differential Lock
Complete Left or Right Turn
Solenoid and Quick Release Valve
After Differential Lock is
Function.
Released Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
WARNING
Sudden machine movement or release of pressurized air can cause
injury to persons on or near machine. Always perform brake system air
pressure release procedure before testing the tractor air system. Failure
to follow this warning may result in injury to personnel.
2. Release brake system air pressure
(WP 0334). Close valves after
releasing air pressure.
3. Disconnect hose (Figure 4, Item 2)
from fitting (Figure 4, Item 1).
Figure 4. Disconnecting Hose From Differential.