TM 5-3805-296-23-2
0111
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is
Released Continued.
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Inspect differential lock air supply
Machine Cannot Make
tube (Figure 1, Item 1), hose
Complete Left or Right Turn
After Differential Lock is
(WP 0271).
(Figure 1, Item 2) for leaks,
Released Continued
Proceed to Test Step 6.
restrictions, and damage
Tube Restricted or Damaged
(WP 0280).
Replace tube (WP 0280).
Proceed to Test Step 6.
Hose Restricted or Damaged Repair
or replace as necessary (WP 0280).
Proceed to Test Step 6.
No Problem Found Proceed to
step 5.
Figure 1. Differential Lock Air Supply Components.
0111