TM 5-3805-296-23-2
0110
Table 1. Machine Turns When Differential Lock Is Engaged Continued.
0110
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 19. Verify Malfunction is
Machine Turns When
Resolved.
Differential Lock Is Engaged
1. Ensure all harness connectors are
Continued
connected.
2. Operate machine and verify proper
Differential Lock Operates Properly
operation of differential lock
Proceed to step 3.
(TM 5-3805-296-10).
Machine Turns When Differential
Lock is Engaged Repeat
troubleshooting from the beginning.
3. If lowered, install left frame access
plate (WP 0376) and cover
(Figure 3, Item 6).
4. Troubleshooting complete.
END OF WORK PACKAGE
0110-18