TM 5-3805-296-23-2
0110
Table 1. Machine Turns When Differential Lock Is Engaged Continued.
0110
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
8. Connect connector W-C11
Machine Turns When
(WP 0012, Figure 69) to right
Differential Lock Is Engaged
differential lock switch connector
Continued
(WP 0012, Figure 68).
9. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
10. Press and release right differential
lock switch (TM 5-3805-296-10).
11. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
12. Remove fuse F33 from circuit
breaker panel
(TM 5-3805-296-10).
Continuity Install fuse F33 on circuit
(WP 0540), test for continuity
breaker panel (TM 5-3805-296-10).
between terminals of fuse F33.
Proceed to Test Step 19.
No Continuity Discard fuse F33.
Proceed to Test Step 14.
Test Step 14. Test for Shorted Fuse
Panel Wiring Harness.
1. Disconnect connector CG-C1
(WP 0012, Figure 283) from
connector W-C8
(WP 0012, Figure 282).
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
harness (WP 0515). Install new fuse
between connector CG-C1
F33 on circuit breaker panel
terminal 10 (WP 0012, Figure 283)
(TM 5-3805-296-10).
and all other terminals in
Proceed to Test Step 19.
connector CG-C1
No Continuity Proceed to step 3.
(WP 0012, Figure 283).
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
harness (WP 0515). Install new fuse
between connector CG-C1
F33 on circuit breaker panel
terminal 10 (WP 0012, Figure 283)
(TM 5-3805-296-10).
and ground.
Proceed to Test Step 19.
No Continuity Proceed to Test
Step 15.
Test Step 15. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector W-C11
(WP 0012, Figure 69) from right
differential lock switch connector
(WP 0012, Figure 68).
0110-15