• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 5. Assembling Test Gauge and Hose.
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is Released Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  636    637    638    639    640  641  642    643    644    645    646  
img
TM 5-3805-296-23-2
0111
Table 1. Machine Cannot Make Complete Left or Right Turn After Differential Lock Is
Released Continued.
0111
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Machine Cannot Make
7. Turn ignition switch and battery
Complete Left or Right Turn
disconnect switch to OFF position
After Differential Lock is
(TM 5-3805-296-10).
Released Continued
8. Connect connector W-C24
(WP 0012, Figure 63) to differential
lock solenoid connector
(WP 0012, Figure 62).
9. Turn battery disconnect switch to
ON position and start engine.
Allow tractor air system to charge
to normal operating pressure
(TM 5-3805-296-10).
10. View pressure reading on gauge
Gauge Reading Changes
(Figure 5, Item 2) while having
Accordingly Remove test hose and
assistant press and release left
gauge from hose. Replace differential
differential lock switch
(WP 0276).
(TM 5-3805-296-10). Gauge
Proceed to Test Step 6.
should read air pressure when
Gauge Reading Fails to Change
switch is pressed. Air pressure
Accordingly Remove test hose and
should bleed off to zero when
gauge from hose and connect hose on
switch is released.
fitting. Replace quick release valve
(WP 0269).
Proceed to Test Step 6.
0111-10


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.