Table 1. 0819 Display Data Link Diagnostic Code Continued.
Table 1. 0821 Display Power Supply Diagnostic Codes.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  490    491    492    493    494  495  496    497    498    499    500  
img
. .
12
TM 5-3805-296-23-2
0100
TROUBLESHOOTING PROCEDURES
-
0821 DISPLAY POWER SUPPLY DIAGNOSTIC CODES
0100
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
WP 0012
0
(WP 0550, Item 181)
WP 0506
0
0
Adapter, Communication
WP 0510
0
(WP 0550, Item 3)
WP 0540
0
0
Multimeter, Digital (WP 0550, Item 107)
0
Equipment Conditions
Software Kit (ET)
0
Machine parked (TM 5-3805-296-10)
(WP 0550, Item 168)
0
0
Test Set, Electronic (MSD)
MSD connected (WP 0008)
0
(WP 0550, Item 175)
0
Tip, Needle (WP 0550, Item 178)
0
Materials/Parts
0
Rag, Wiping (WP 0549, Item 28)
0
Tag, Marker (WP 0549, Item 38)
0
GENERAL
000100
This work package contains field maintenance troubleshooting information for the Military 621G Scraper. Each
malfunction or symptom is followed by the possible cause(s) and suggested remedy or remedies. Use this work
package to help isolate and correct system problems. Ensure all PMCS and operator troubleshooting procedures
(TM 5-3805-296-10) have been performed.