TM 5-3805-296-23-2
0099
Table 1. 0819 Display Data Link Diagnostic Code Continued.
099
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 11. Verify Operation of
0819-02 Display Data Link
Quad Gauge Display Module.
Erratic, Intermittent, or
Module Fails to Power Up or One or
Verify operation of quad gauge display
Incorrect Continued
More Gauges Function Improperly
module by performing Monitoring
Replace quad gauge display module
System Self-test (WP 0177).
(WP 0506).
Proceed to Test Step 12.
No Problem Found Replace tractor
operator monitor (WP 0506).
Proceed to Test Step 12.
Test Step 12. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
263-3 Digital Sensor Power Supply
diagnostic codes (WP 0008).
(8V or 12V) Voltage Above Normal
Becomes Inactive Proceed to step 4.
263-3 Digital Sensor Power Supply
(8V or 12V) Voltage Above Normal
Remains Active Repeat
troubleshooting from the beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. Install instrument panel
(Figure 2, Item 3) with six bolts
(Figure 2, Item 4) on ROPS
(Figure 2, Item 5).
6. Install right vent (Figure 2, Item 7)
with two bolts (Figure 2, Item 6) on
instrument panel
(Figure 2, Item 3).
7. Install left vent (Figure 2, Item 2)
with two bolts (Figure 2, Item 1) on
instrument panel (Figure 2, Item 3)
8. Install instrument panel cover
(Figure 1, Item 3) with six washers
(Figure 1, Item 2) and bolts
(Figure 1, Item 1) on ROPS
(Figure 1, Item 4).
9. Troubleshooting complete.
END OF WORK PACKAGE
0099-10