TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
NOTE
1276-13 Bowl Down
Solenoid Out of Calibration
Perform this test only if condition is active.
DIAGNOSTIC CODE SET CONDITION
Transmission/Chassis ECM Detects Bowl Down Solenoid Out of Calibration.
POSSIBLE CAUSE
Bowl Down Solenoid Requires Calibration.
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Test Step 1. Test Calibration Tool.
Monitor Implement Pump Pressure
Status Remains Low Proceed to
Status (Figure 13, Item 1) while
Test Step 2.
performing ejector solenoid calibration
Status Changes From Low to High
(WP 0173).
Proceed to Test Step 5.
Figure 13. Implement Pump Pressure Status.
0071
Test Step 2. Test Transmission
or Open.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Disconnect test equipment
from connector A-C12
(WP 0012, Figure 103).
3. Connect jumper wire between
terminal B and terminal C
of connector A-C12
(WP 0012, Figure 103).
4. Disconnect connector A-C1
(WP 0012, Figure 106)
from connector J-C3
(WP 0012, Figure 101).