Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
APRON RAISE PROPORTIONAL SOLENOID DIAGNOSTIC CODES

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  92    93    94    95    96  97  98    99    100    101    102  
img
TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 5. Perform Bowl Solenoid
1276-13 Bowl Down
Calibration.
Solenoid Out of Calibration
Continued
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform bowl solenoid calibration
Calibration Successful
(WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
Calibrating (never completes
process) Proceed to Test Step 6.
Calibration Value Too Low Replace
bowl down solenoid (WP 0436).
Calibrate bowl solenoid (WP 0173).
Calibration Value Too Large
Replace bowl down solenoid
(WP 0436).
Calibrate bowl solenoid (WP 0173).
Test Step 6. Perform Joystick Bowl
Lever Sensor Calibration.
CAUTION
Failure to hold joystick in proper position during calibration will create
invalid test results.
Perform joystick bowl lever sensor
Calibration Successful
calibration (WP 0173).
Troubleshooting complete.
Active Diagnostic Code Present
Diagnose and repair active code
(WP 0005).
Repeat troubleshooting from the
beginning.
Calibration Value Too Low Replace
implement control joystick (WP 0503).
Calibrate joystick (WP 0173).
Calibration Value Too Large
Replace implement control joystick
(WP 0503).
Calibrate joystick (WP 0173).
END OF WORK PACKAGE
0071-27/(28 blank)