Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
Figure 13. Implement Pump Pressure Status.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  89    90    91    92    93  94  95    96    97    98    99  
img
TM 5-3805-296-23-2
0071
Table 1. 1276 Bowl Down Proportional Solenoid Diagnostic Codes Continued.
071
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Verify Malfunction is
1276-06 Bowl Down
Resolved.
Solenoid Current Above
1. Ensure all harness connectors are
Normal Continued
connected.
2. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
3. At MSD, check for active
1276-6 Bowl Down Solenoid Current
diagnostic codes (WP 0008).
Above Normal Becomes Inactive
Proceed to step 4.
1276-6 Bowl Down Solenoid Current
Above Normal Remains Active
Repeat troubleshooting from the
beginning.
4. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
5. If removed, install splash shield
(Figure 12, Item 4), four bushings
(Figure 12, Item 3), washers
(Figure 12, Item 2), and bolts
(Figure 12, Item 1) on machine.
6. If lowered, install left frame access
plate (WP 0376).
7. Install rear cover
(Figure 11, Item 3), two washers
(Figure 11, Item 2), and bolts
(Figure 11, Item 1) on machine.
8. Install cover (Figure 10, Item 3),
four washers (Figure 10, Item 1),
and bolts (Figure 10, Item 2) on
machine.
9. Install hydraulic tube clamp
(Figure 9, Item 4), two washers
(Figure 9, Item 2), and bolts
(Figure 9, Item 3) on mounting
boss (Figure 9, Item 1) and
hydraulic tube (Figure 9, Item 5).
10. Troubleshooting complete.