Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes.
Figure 2. Splash Shield and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  95    96    97    98    99  100  101    102    103    104    105  
img
.
TM 5-3805-296-23-2
0072
Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes Continued.
072
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted
1277-03 Apron Raise
Implement Wiring Harness.
Solenoid Voltage Above
1. Turn ignition switch and battery
Normal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove four bolts
(Figure 1, Item 2), washers
(Figure 1, Item 1), and front cover
(Figure 1, Item 3) from machine.
Figure 1. Front Cover.
0072
3. Disconnect connector F-C2
(WP 0012, Figure 150) from apron
raise solenoid connector
(WP 0012, Figure 149).
4. Disconnect connector F-C8
(WP 0012, Figure 146)
from connector AE-C5
(WP 0012, Figure 145).