TM 9-4940-568-34
7-82
7-10. GENERATOR REPAIR (CONT).
b.
Assembly.
NOTE
Pin may need to be pressed in for
installation.
(1)
If necessary, install pin (22) on rotor
assembly (20).
NOTE
Bearing may need to be pressed
in for assembly.
(2)
Install bearing (21) on rotor assembly (20).
(3)
Install rotor assembly (20) into generator
(3).
NOTE
Position wire lead as noted prior
to removal.
(4)
Install end bell (19) on generator (3).
(5)
Install six washers (18), lockwashers (17)
and screws (16) on end bell (19) and
generator (3).
(6)
Tighten screws (16) to 25 lb-ft (11 N.m).
Use extreme care when removing
or installing spring retaining
rings. Spring retaining rings are
under tension and can act as
projectiles when released
suddenly. Ensure proper eye
protection is worn to prevent
injury to personnel.
(7)
Install retaining ring (14) on shaft (15).
(8)
Remove PMG mount screw (11) from shaft
(15).
3
15
14
16
17
18
19
20
3
11
21
20
22