TM 9-4940-568-34
5-151
(7)
Repeat Steps (5) and (6) until a total of
two grounded brushes (17) and two
insulated brushes (18) are installed.
(8)
Position the terminals of two grounded
brush (17) leads behind the terminal tabs
on brush holder assembly (7).
(9)
Insert two grounded brush screws (20)
through the terminal tabs on brush holder
assembly (7) and thread into two
grounded brush (17) lead terminals.
Tighten grounded brush screws to 13
lb-in (1.5 N.m).
(10)
Position brush holder assembly (7) (with
installed brushes) over terminal end of
frame and field assembly (9).
(11)
Attach terminals of two insulated brush
(18) leads to conductors in frame and
field assembly (9) and insert two
insulated brush screws (19). Tighten
insulated brush screws to 13 lb-in (1.5
N.m).
7
17
18
18
17
9
19
19
20
20