TM 9-4940-568-20
3-66
3-16. WIRING HARNESS MAINTENANCE (CONT).
13
13
15
17
14
26
26
NOTE
Crimping tool must be readjusted for each type and/or size contact.
(17)
To insert contact(s) (15) into plug (13), position plug (13) with rear toward you.
(18)
Insert contact(s) (15) into plug (13) and push until contact (15) stops.
(19)
Pull on wire (17) to confirm that contact (15) is locked in place.
(20)
Repeat Steps (17) thru (19) as many times as needed until all contacts (15) are installed.
(21)
Install sealing plugs (26) into any unused holes in plug (13) and receptacle (14).
NOTE
If plug and receptacle had adhesive on it and a heat gun is not available, perform Steps
(22) and (23) then continue with Step (25).
If plug receptacle had adhesive on it and a heat gun is available, perform steps (22) and
(24) then continue with Step (25).
If plug and receptacle did not have adhesive on it, go to Step (25).
(22)
Clean back of plug (13), receptacle (14) and wires (17) with alcohol and allow to dry.
(23)
Apply silicone sealant to seal back of plug (13), receptacle (14) and wires (17). Cover all parts fully.
To prevent personal injury, allow adhesive to cool before handling.
(24)
Using heat gun (11) apply adhesive to back of plug (13), receptacle (14) and wires (17). Cover all parts
fully.
(25)
If receptacle (14) was repaired or replaced, install it on mounted surface.
(26)
Connect plug (13) to receptacle (14).