TM 9-2330-238-14
4-17. POWER INLET HOUSING AND CABLE CONNECTOR REPLACEMENT (Cont).
6.
Remove cable connector (16) with wires (1) from
inside receptacle (7). Remove box connector (10)
from receptacle.
b. CLEANING AND INSPECTION
1.
Clean all parts with a soap and water solution. Dry
thoroughly.
2.
Inspect for cracks, breaks, broken insulation, bare
wires, or other damage.
3.
Replace defective parts.
c.
INSTALLATION
1.
2.
3.
4.
5.
6.
7.
.
NOTE
Steps 1-4 describe installation of conduit and
cable connector between electrical box and re-
ceptacle, for M447, M447C, M750, and early
model M313. Installation procedures are simi-
lar for all other models; only minor differences
in configuration exist.
Install box connector (10) on receptacle (7).
Feed cable connector (16) with wires (1) through
conduit (5) and receptacle (7) and seat cable
connector in receptacle end.
Tighten nut (6) to secure conduit (5) to box
connector (10) at receptacle (7).
M447, M447C, M750, AND M313 (EARLY MODEL)
Secure conduit (5) to box connector (3) at electrical box (2) by tightening nut (4).
NOTE
M749 Southwest Model VRP Serial Numbers V001-V356 (100-volt) and Serial
Numbers V549-V628, and Converto Model 8929 have two nuts, Iockwashers, and
screws.
Install cover (17) on cable connector (16) and van body (9), junction box (13), or power inlet housing (18) with
four screws (8), new Iockwashers (15), and nuts (14).
On late model M313, install access plate (12) on junction box (13) with four screws (11).
Connect wires (1) of cable connector (16), as tagged, to electrical components inside electrical box (2). Close
electrical box.
TA701940
4-25