4-24
TM 9-2330-238-14
4-17. POWER INLET HOUSING AND CABLE CONNECTOR REPLACEMENT (Cont).
2.
3.
4.
5.
On late model M313, remove four screws (11) and access plate (12) from junction box(13) inside semitrailer.
NOTE
M749 Southwest Model VRP Serial Numbers
V001-V356 (110-volt) and Serial Numbers
V549-V628, and Converto Model 8929 have
two nuts, Iockwashers, and screws.
Remove four nuts (14), Iockwashers (15), screws
(8), and cover (17) from cable connector (16) and
van body (9), junction box (13), or power inlet
housing (18). Discard Iockwashers.
NOTE
Steps 4-6 describe removal of conduit and
cable connector from between electrical box
and receptacle, for M447, M447C, M750, and
early model M313. Removal procedures are
similar for all other models; only minor differ-
ences in configuration exist.
4
Loosen nut (4) from box connector (3) at electrical
box (2). Remove conduit (5) with assembled
receptacle (7) and cable connector (16) with wires
M313 (LATE MODEL)
(1) from electrical box and van body (9).
Loosen nut (6) and separate conduit (5) from box connector (10) at receptacle (7).
M447, M447C, M750, AND M313 (EARLY MODEL)
M749 SOUTHWEST MODEL VRP SERIAL
NUMBERS V001-V356 (110-VOLT)
TA701939