TM 5-3895-376-14&P
5-17. GOVERNOR ASSEMBLY MAINTENANCE INSTRUCTlONS - Continued
INSPECTION
CLEANING
1
Visually inspect governor (8) for missing or bro-
WARNING
ken springs (3 and 4) Replace spring set if any
spring is broken or missing.
P-D-680, Type III, is moderately toxic to
the skin. eyes and respiratory tract:
2
Inspect governor pin (1) for scoring or bent condi-
avoid prolonged exposure. Skin and
tion. Replace a damaged pin.
eye protection is requited. Good ventila-
tion is required. Do not use near open
flame or excessive heat. Flash point is
200F (93.3C).
1. Clean the governor assembly and pin in dry
cleaning solvent and dry thoroughly.
5-50