• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Scraper Air Pressure Sensor Relay and Sensor.
Figure 4. Scraper Air Pressure Sensor Relay.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  783    784    785    786    787  788  789    790    791    792    793  
img
.
TM 5-3805-296-23-5
0346
INSTALLATION
000346
WARNING
Wheels must remain chocked during entire procedure. Failure to follow this warning may
result in injury or death to personnel.
CAUTION
Do not disconnect jumper harness from scraper air pressure sensor. Scraper air pressure
sensor damage will occur.
NOTE
Remove plugs and caps from hoses and fittings.
1. Do not disconnect connector (Figure 3, Item 2) from scraper air pressure sensor (Figure 3, Item 3).
2. Position relay (Figure 3, Item 1) and scraper air pressure sensor (Figure 3, Item 3) on machine.
3. Install new O-ring (Figure 3, Item 4) and scraper air pressure sensor (Figure 3, Item 3) on fitting
(Figure 3, Item 5).
Figure 3. Scraper Air Pressure Sensor Relay and Sensor.
0346
0346-4