SCRAPER AIR PRESSURE SENSOR REPLACEMENT
Figure 2. Scraper Air Pressure Sensor Relay and Sensor.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  781    782    783    784    785  786  787    788    789    790    791  
img
.
TM 5-3805-296-23-5
0346
REMOVAL
000346
WARNING
Wheels must remain chocked during entire procedure. Failure to follow this warning may
result in injury or death to personnel.
CAUTION
Plug and cap all hoses and fittings to prevent contamination. Failure to follow this caution
may result in equipment damage.
NOTE
Tag and mark wiring harness connectors to aid with installation.
1. Disconnect push frame wiring harness connector (Figure 1, Item 8) from scraper air pressure sensor
connector (Figure 1, Item 1).
2. Remove bolt (Figure 1, Item 6), washer (Figure 1, Item 5), bracket (Figure 1, Item 2), clamp (Figure 1, Item 3)
and relay (Figure 1, Item 4) from mounting boss (Figure 1, Item 7) and position aside.