• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 24. NATO Slave Receptacle Cable and Solargizer Terminal.
Figure 1. Right Starter Cable P-clamp at Frame by Junction Block.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  243    244    245    246    247  248  249    250    251    252    253  
img
.
30
TM 5-3805-296-23-5
0310
FIELD MAINTENANCE
-
STARTER POSITIVE CABLES AND JUNCTION BLOCK REPLACEMENT
0
310
Right Starter Positive Cable Removal, Left Starter Positive Cable Removal, Junction Block Removal,
Cleaning and Inspection, Junction Block Installation,
Left Starter Positive Cable Installation, Right Starter Positive Cable Installation
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-3805-296-10)
0
(WP 0550, Item 181)
Front hood opened (TM 5-3805-296-10)
0
0
Goggles, BII Item (TM 5-3805-296-10)
Right engine doors opened
0
(TM 5-3805-296-10)
0
Materials/Parts
0
Drawings Required
Rag, Wiping (WP 0549, Item 28)
0
0
Tag, Marker (WP 0549, Item 38)
RPSTL Figure 86
0
0
Tiedown Strap (WP 0549, Item 41)
0
Estimated Time to Complete
0
References
3.0 hr
0
0
TM 9-6140-200-13
0
References
0
WP 0205
0
WP 0374
0
0310-1