• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
STARTER POSITIVE CABLES AND JUNCTION BLOCK REPLACEMENT
Figure 2. Right Starter Cable at Junction Block.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  244    245    246    247    248  249  250    251    252    253    254  
img
.
TM 5-3805-296-23-5
0310
WARNING
Make sure battery disconnect switch is in OFF position before replacing starter cables.
Failure to follow this warning may result in injury or death to personnel or damage to
equipment.
RIGHT STARTER POSITIVE CABLE REMOVAL
000310
1. Remove muffler (WP 0205).
NOTE
Note cable routing to aid in installation.
2. Remove bolt (Figure 1, Item 1), washer (Figure 1, Item 2), and P-clamp (Figure 1, Item 3) from boss
(Figure 1, Item 4).
3. Position right starter cable (Figure 1, Item 5) aside.
Figure 1. Right Starter Cable P-clamp at Frame by Junction Block.
0310
0310-2


Privacy Statement