Table 1. Right Front Turn Signal Does Not Operate Continued.
Table 1. Right Front Turn Signal Does Not Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  1051    1052    1053    1054    1055  1056  1057    1058    1059    1060    1061  
img
.
TM 5-3805-296-23-2
0145
Table 1. Right Front Turn Signal Does Not Operate Continued.
0145
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Remove two bolts
Right Front Turn Signal
(Figure 3, Item 1) and left vent
Does Not Operate
(Figure 3, Item 2) from instrument
Continued
panel (Figure 3, Item 3).
4. Remove two bolts
(Figure 3, Item 6) and right vent
(Figure 3, Item 7) from instrument
panel (Figure 3, Item 3).
5. Remove six bolts (Figure 3, Item 4)
from instrument panel
(Figure 3, Item 3) and ROPS
(Figure 3, Item 5). Position
instrument panel to
access connector P-C18
(WP 0012, Figure 269).
Figure 3. Instrument Panel and Retaining Hardware.