• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Right Front Turn Signal Does Not Operate Continued.
Table 1. Right Front Turn Signal Does Not Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  1049    1050    1051    1052    1053  1054  1055    1056    1057    1058    1059  
img
TM 5-3805-296-23-2
0145
Table 1. Right Front Turn Signal Does Not Operate Continued.
0145
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Using digital multimeter
Right Front Turn Signal
Continuity Replace chassis wiring
(WP 0540), test for continuity
Does Not Operate
harness (WP 0305).
between connector J-C8
Continued
Proceed to Test Step 13.
terminal 40 (WP 0012, Figure 100)
No Continuity Proceed to Test
and ground.
Step 10.
Test Step 10. Test for Shorted Main
Cab Wiring Harness.
1. Remove upper plenum from ROPS
(WP 0504).
2. Disconnect connector P-C1
(WP 0012, Figure 253) from
connector W-C7
(WP 0012, Figure 252).
3. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C1
Proceed to Test Step 13.
terminal 40 (WP 0012, Figure 99)
No Continuity Proceed to step 4.
and all other terminals
in connector W-C1
(WP 0012, Figure 99).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C7
Proceed to Test Step 13.
terminal 8 (WP 0012, Figure 252)
No Continuity Proceed to step 5.
and all other terminals
in connector W-C7
(WP 0012, Figure 252).
5. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C7
Proceed to Test Step 13.
terminal 8 (WP 0012, Figure 252)
No Continuity Proceed to Test
and ground.
Step 11.
0145-7