Table 1. Right Front Turn Signal Does Not Operate Continued.
Table 1. Right Front Turn Signal Does Not Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  1048    1049    1050    1051    1052  1053  1054    1055    1056    1057    1058  
img
TM 5-3805-296-23-2
0145
Table 1. Right Front Turn Signal Does Not Operate Continued.
0145
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 8. Test for Shorted Hood
Right Front Turn Signal
Wiring Harness.
Does Not Operate
Continued
1. Turn right turn signal OFF
(TM 5-3805-296-10).
2. Turn mode switch on military light
switch to OFF position
(TM 5-3805-296-10).
3. Turn battery disconnect switch to
OFF position (TM 5-3805-296-10).
4. Disconnect connector L-C5
(WP 0012, Figure 211)
from right front signal lamp
(WP 0012, Figure 210).
5. Disconnect connector L-C2
(WP 0012, Figure 192)
from connector J-C1
(WP 0012, Figure 191).
6. Using digital multimeter
Continuity Replace hood wiring
(WP 0540), test for continuity
harness (WP 0389).
between connector L-C2
Proceed to Test Step 13.
terminal 5 (WP 0012, Figure 192)
No Continuity Proceed to step 7.
and all other terminals
in connector L-C2
(WP 0012, Figure 192).
7. Using digital multimeter
Continuity Replace hood wiring
(WP 0540), test for continuity
harness (WP 0389).
between connector L-C2
Proceed to Test Step 13.
terminal 5 (WP 0012, Figure 192)
No Continuity Proceed to Test
and ground.
Step 9.
Test Step 9. Test for Shorted Chassis
Wiring Harness.
1. Disconnect connector J-C8
(WP 0012, Figure 100)
from connector W-C1
(WP 0012, Figure 99).
2. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C1 terminal 5
Proceed to Test Step 13.
(WP 0012, Figure 191) and all
No Continuity Proceed to step 3.
other terminals in connector J-C1
(WP 0012, Figure 191).
3. Using digital multimeter
Continuity Replace chassis wiring
(WP 0540), test for continuity
harness (WP 0305).
between connector J-C8
Proceed to Test Step 13.
terminal 40 (WP 0012, Figure 100)
No Continuity Proceed to step 4.
and all other terminals
in connector J-C8
(WP 0012, Figure 100).
0145-6