TM 5-3805-296-23-2
0110
Table 1. Machine Turns When Differential Lock Is Engaged Continued.
0110
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Inspect differential lock air supply
Machine Turns When
tube (Figure 1, Item 1), hose
Differential Lock Is Engaged
Continued
(WP 0271).
(Figure 1, Item 2) for leaks,
Proceed to Test Step 19.
restrictions, and damage
Tube/Hose Connection(s) Leaking
(WP 0280).
Tighten or repair as necessary
(WP 0280).
Proceed to Test Step 19.
Tube Restricted or Damaged
Replace tube (WP 0280).
Proceed to Test Step 19.
Hose Restricted or Damaged Repair
or replace as necessary (WP 0280).
Proceed to Test Step 19.
No Problem Found Proceed to
step 5.
Figure 1. Differential Lock Air Supply Components.
0110