TM 5-3805-296-23-2
0110
Table 1. Machine Turns When Differential Lock Is Engaged Continued.
0110
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Have assistant press left
Machine Turns When
Voltage 18 to 25 V Have assistant
differential lock switch
Differential Lock Is Engaged
release left differential lock switch.
(TM 5-3805-296-10). With switch
Continued
Proceed to step 7.
Voltage Less Than 18 V Have
(WP 0540) to test for voltage
assistant release left differential lock
between connector W-C24
switch. Proceed to Test Step 16.
terminal 1 (WP 0012, Figure 63)
and ground.
7. Have assistant press right
Voltage 18 to 25 V Have assistant
differential lock switch
release right differential lock switch.
(TM 5-3805-296-10). With switch
Proceed to Test Step 7.
Voltage Less Than 18 V Replace
(WP 0540) to test for voltage
right differential lock switch (WP 0514).
between connector W-C24
Proceed to Test Step 19.
terminal 1 (WP 0012, Figure 63)
and ground.
Test Step 7. Test Ground Circuit
Function.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
measure resistance between
Proceed to Test Step 8.
connector W-C24 terminal 2
(WP 0012, Figure 63) and ground.
Proceed to Test Step 17.
0110-7