Figure 2. Differential Lock Air Supply Components.
Table 1. Machine Turns When Differential Lock Is Engaged Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  613    614    615    616    617  618  619    620    621    622    623  
img
.
TM 5-3805-296-23-2
0110
Table 1. Machine Turns When Differential Lock Is Engaged Continued.
0110
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Pivot cover (Figure 3, Item 4).
Machine Turns When
Quick Release Valve Leaking or
Inspect differential lock air supply
Differential Lock Is Engaged
Damaged Replace quick release
hose (Figure 3, Item 1), quick
Continued
valve (WP 0269).
release valve (Figure 3, Item 2),
Proceed to Test Step 19.
and hose (Figure 3, Item 3) for
Hose Connection(s) Leaking
leaks, restrictions, and damage
Tighten or repair as necessary
(WP 0280 and WP 0269).
(WP 0280).
Proceed to Test Step 19.
Hose(s) Restricted or Damaged
Repair or replace as necessary
(WP 0280).
Proceed to Test Step 19.
No Problem Found Proceed to Test
Step 4.
Figure 3. Differential Lock Air Supply Components.
0110