• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Battery Disconnect Switch and Negative Cables.
Figure 3. Testing Voltage to Fuse F13.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  518    519    520    521    522  523  524    525    526    527    528  
img
.
TM 5-3805-296-23-2
0104
Table 1. Engine Will Not Crank Continued.
0104
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine WIll Not Crank
9. Turn battery disconnect switch to
Continued
OFF position (TM 5-3805-296-10).
10. Disconnect battery negative cable
(Figure 2, Item 6) from ground
(Figure 2, Item 7).
11. Disconnect battery negative cable
(Figure 2, Item 3) from battery
(Figure 2, Item 8) and battery
(Figure 2, Item 2).
12. Turn battery disconnect switch to
ON position (TM 5-3805-296-10).
13. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Replace battery negative cables
between terminal (Figure 2,
(WP 0307).
Item 4) and terminal (Figure 2,
Proceed to Test Step 27.
Item 5).
Resistance Greater Than 5.0 Ohms
Replace battery disconnect switch
(WP 0312).
Proceed to Test Step 27.
Figure 2. Battery Cables and Battery Disconnect Switch.
0104
0104-5


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.