• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. Instrument Panel and Retaining Hardware.
Figure 5. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  423    424    425    426    427  428  429    430    431    432    433  
img
.
TM 5-3805-296-23-2
0094
Table 1. 0177 Transmission Oil Temperature Sensor Diagnostic Code - Continued.
0094
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0177-08 Transmission Oil
9. Install instrument panel cover
Temperature Sensor
(Figure 4, Item 3) with six washers
Abnormal Frequency, Pulse
(Figure 4, Item 2) and bolts
Width, or Period
(Figure 4, Item 1) on ROPS
Continued
(Figure 4, Item 4).
Figure 4. Instrument Panel Cover and Retaining Hardware.
0094
10. Install lower and upper plenum on
ROPS (WP 0504).
11. Install crankcase guard
(WP 0374).
Test Step 6. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Start and run engine to normal
177-8 Transmission Oil Temperature
operating temperature
Sensor Abnormal Frequency, Pulse
(TM 5-3805-296-10) while
Width, or Period Becomes Inactive
monitoring MSD for active
Troubleshooting complete. Proceed to
diagnostic codes (WP 0008).
step 3.
177-8 Transmission Oil Temperature
Sensor Abnormal Frequency, Pulse
Width, or Period Remains Active
Replace tractor operator monitor
(WP 0506).
Proceed to Test Step 16.
0094-9