TM 5-3805-296-23-1
0054
Table 1. 0144 Backup Alarm Diagnostic Code Continued.
054
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test Fuse Panel Wiring
0144-05 Backup Alarm
Harness for High Resistance or
Backup Alarm Relay Current
Open.
Below Normal Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Install flood enable relay on flood
enable relay connector on fuse
panel (Figure 2). Do not install
backup alarm relay at this time.
3. Disconnect connector CG-C1
from connector W-C8
4. Connect jumper wire between
terminal E15 and terminal C16 of
backup alarm relay connector
(Figure 3).
(WP 0540), measure resistance
Proceed to Test Step 3.
between connector CG-C1
terminal 19 and terminal 20
Replace fuse panel wiring harness
(WP 0515).
Proceed to Test Step 4.
Figure 3. Backup Alarm Relay Connector Terminals on Fuse Panel.
0054