Table 1. 0144 Backup Alarm Diagnostic Code Continued.
Table 1. 0144 Backup Alarm Diagnostic Code Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  767    768    769    770    771  772  773    774    775    776    777  
img
. .
TM 5-3805-296-23-1
0054
Table 1. 0144 Backup Alarm Diagnostic Code Continued.
054
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Backup
0144-06 Backup Alarm Relay
Alarm Relay.
Current Above Normal
1. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove backup alarm relay from
fuse panel (Figure 4).
3. Remove flood enable relay from
fuse panel (Figure 4). Install flood
enable relay on backup alarm
relay connector on fuse panel.
Figure 4. Backup Alarm Relay and Flood Enable Relay.
0054
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
144-6 Backup Alarm Relay Current
5. At MSD, check for active
Above Normal Becomes Inactive
diagnostic code 144-6 Backup
Replace backup alarm relay.
Alarm Relay Current Above
Proceed to Test Step 4.
Normal (WP 0008).
144-6 Backup Alarm Relay Current
Above Normal Remains Active
Proceed to Test Step 2.
0054-10


Privacy Statement