TM 5-3805-296-23-1
0054
Table 1. 0144 Backup Alarm Diagnostic Code Continued.
054
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 3. Test Main Cab Wiring
0144-05 Backup Alarm
Harness for High Resistance or
Backup Alarm Relay Current
Open.
Below Normal Continued
1. Remove jumper wire from terminal
E15 and terminal C16 of backup
alarm relay connector (Figure 3).
2. Connect jumper wire between
terminal 19 and terminal 20
of connector W-C8
3. Disconnect connector W-C13
transmission/chassis ECM.
(WP 0540), measure resistance
Replace transmission/chassis ECM
between connector W-C13
(WP 0495).
terminal 12 and terminal 16
Proceed to Test Step 4.
Replace main cab wiring harness
(WP 0505).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. Ensure backup alarm relay and
flood enable relay are installed on
fuse panel.
3. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
4. At MSD, check for active
144-5 Backup Alarm Relay Current
Below Normal Becomes Inactive
Troubleshooting complete.
144-5 Backup Alarm Relay Current
Below Normal Remains Active
Repeat troubleshooting from the
beginning.