Table 1. 0144 Backup Alarm Diagnostic Codes.
Table 1. 0144 Backup Alarm Diagnostic Code Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  760    761    762    763    764  765  766    767    768    769    770  
img
. .
TM 5-3805-296-23-1
0054
Table 1. 0144 Backup Alarm Diagnostic Code Continued.
054
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
2. Remove backup alarm relay from
0144-03 Backup Alarm Relay
fuse panel (Figure 1).
Voltage Above Normal
Continued
3. Remove flood enable relay from
fuse panel (Figure 1). Install flood
enable relay on backup alarm
relay connector on fuse panel.
Figure 1. Backup Alarm Relay and Flood Enable Relay.
0054
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
5. At MSD, check for active
144-3 Backup Alarm Relay Voltage
diagnostic code 144-3 Backup
Above Normal Becomes Inactive
Alarm Relay Voltage Above
Replace backup alarm relay.
Normal (WP 0008).
Proceed to Test Step 4.
144-3 Backup Alarm Relay Voltage
Above Remains Active Proceed to
Test Step 2.
0054-3