Table 1. 0144 Backup Alarm Diagnostic Code Continued.
054
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 2. Test for Shorted Fuse
0144-03 Backup Alarm Relay
Panel Wiring Harness.
Voltage Above Normal
1. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Install flood enable relay on flood
enable relay connector on fuse
panel (Figure 1). Do not install
backup alarm relay at this time.
3. Disconnect connector CG-C1
Figure 282).
Continuity Replace fuse panel wiring
(WP 0540), test for continuity
harness (WP 0515).
between connector CG-C1
Proceed to Test Step 4.
No Continuity Proceed to Test
and all other terminals in
Step 3.
Figure 283).
Test Step 3. Test for Shorted Main
Cab Wiring Harness.
1. Disconnect connector W-C13
transmission/chassis ECM.
2. Disconnect connector W-C12
transmission/chassis ECM.
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C8
Proceed to Test Step 4.
No Continuity Proceed to step 4.
and all other terminals
in connector W-C8
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505).
between connector W-C13
Proceed to Test Step 4.
No Continuity Proceed to step 5.
and all other terminals
in connector W-C13
0054-4