Table 1. 0562 Module Communication Diagnostic Codes.
Figure 2. Instrument Panel and Retaining Hardware.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  657    658    659    660    661  662  663    664    665    666    667  
img
.
TM 5-3805-296-23-1
0037
Table 1. 0562 Module Communication Diagnostic Codes Continued.
037
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test Voltage of Battery
0562-09 Caterpillar
Circuit at Tractor Operator Monitor.
Monitoring System
1. Turn ignition switch and battery
Abnormal Update Rate
disconnect switch to OFF position
Continued
(TM 5-3805-296-10).
2. Remove six bolts
(Figure 1, Item 1), washers
(Figure 1, Item 2), and instrument
panel cover (Figure 1, Item 3) from
ROPS (Figure 1, Item 4).
Figure 1. Instrument Panel Cover and Retaining Hardware.
0037