TM 5-3805-296-23-1
0024
Table 1. 0168 System Voltage Diagnostic Codes Continued.
024
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Voltage 18 to 25 V Proceed to Test
0168-02 Electrical System
Step 5.
(WP 0540), test for voltage
Voltage Erratic, Intermittent,
Voltage Less Than 18 V Proceed to
between CL-C1 terminal 53
or Incorrect Continued
Test Step 8.
Test Step 5. Inspect Ground Points of
Engine Interface Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-296-10).
(WP 0374).
3. Inspect ground points of engine
Ground Point(s) or Ring Terminal(s)
interface wiring harness
Dirty or Corroded Clean as
necessary.
for dirt, corrosion, and damage
Proceed to Test Step 10.
(WP 0540).
Ring Terminal(s) Defective Replace
engine interface wiring harness (WP
0211).
Proceed to Test Step 10.
No Problem Found Install engine
interface wiring harness on ground
points (WP 0211). Proceed to Test
Step 6.
Test Step 6. Verify if Code is Still
Active.
1. Ensure all harness connectors are
connected.
2. Turn battery disconnect switch to
ON position and start engine
(TM 5-3805-296-10).
3. At MSD, check for active
168-2 Electrical System Voltage
diagnostic code 168-2 Electrical
Erratic, Intermittent, or Incorrect
System Voltage Erratic,
Becomes Inactive Troubleshooting
Intermittent, or Incorrect
complete. Proceed to step 4.
168-2 Electrical System Voltage
Erratic, Intermittent, or Incorrect
Remains Active Proceed to Test Step
7.
0024-14