TM 3-4240-302-30&P-1
2-7. COMPARTMENT CONTROL MODULE (CONT).
LOCATION
ITEM
ACTION
REMOVAL
HORN OFF switch K2
Diodes CR4 and CR5
CAUTION
Apply heat sink pliers to leads of diodes
when unsoldering. Excessive heat will
damage the diodes.
2. Unsolder diode CR4 (1) from HORN OFF
switch K2 (2).
3. Unsolder diode CR5 (3) connected between
HORN OFF switch K2 (2) and DS9 (4).
INSTALLATION|
CAUTION
Diodes must be connected properly or
the banded end of the diodes.
CAUTION
Apply heat sink pliers to leads of diodes
damage the diodes.
1. Solder diodes CR4 (1) and CR5 (3). Refer to
2-94