TM 3-4240-302-30&P-1
LOCATION
ITEM
ACTION
INSTALLATION
Panel
OCCUPIED
1. Remove module (2), screws (3), and sleeve (4)
switch/indicator
from switch/indicator light S8/DS5
light S8/DS5
2. Insert housing (1) in panel (5).
3. Place sleeve (4) over housing and install but do
not tighten screws (3).
NOTE
Lamp module is keyed into housing at
only one rotational position. It may be
necessary to turn the lamp module
within the housing to find the keyway.
4. Place module (2) in housing (1) and position
housing in panel (5) with the word OCCUPIED
right side up and horizontal.
5. Remove module (2) and tighten screws (3).
6. Install lamps (6) in module.
7. Reinstall module (2) in housing.
8. Connect and solder wires. Refer to wiring
LOW PRESSURE
Same as OCCUPIED switch/indicator light S8/DS5.
switch/indicator
light S11/DS9
MASK switch/indicator
Same as OCCUPIED switch/indicator light S8/DS5.
light S100/DS11
2-93