ENTRANCE PRESSURE circuit breaker CB6
MAIN FAN circuit breaker CB7

Technical Manual For Compartment Control Module
Page Navigation
  87    88    89    90    91  92  93    94    95    96    97  
img
. . .
TM 3-4240-302-30&P-1
2-7. COMPARTMENT CONTROL MODULE (CONT).
LOCATION
ITEM
ACTION
REMOVAL
Panel
COMPARTMENT
1. Disassemble CCM (p. 2-77).
PRESSURE
2. Remove and tag wire leads from
circuit breaker
COMPARTMENT PRESSURE circuit
breaker CB8 (1).
CB8
3. Unscrew and remove waterproof boot (2), if
present.
4. Remove COMPARTMENT PRESSURE
circuit breaker CB8 (1) and keying washer
(3).
INSTALLATION
1. Insert COMPARTMENT PRESSURE circuit
breaker CB8 (1) with keying washer (3) in
panel (4) and secure with waterproof boot
(2), if necessary.
2. Connect wire leads. Refer to wiring
diagram (p. 2-99).
3. Reassemble CCM (p. 2-77).
2-90