11
12
13
14
15
9
16
10
17
18
7
6
8
4
5
TM 9-4940-568-34
5-107
NOTE
Tag and mark all wires prior to
removal.
Remove cable ties as necessary.
Starting fluid is toxic and highly
flammable. Container is
pressurized. NEVER heat
container and NEVER discharge
starting fluid in confined areas or
near open flame. Severe injury
to personnel may result.
(2)
Remove ether supply cylinder (5) by turning
counterclockwise from ether start aid
assembly (6).
(3)
Remove two screws (7), nuts (8) and ether
start aid assembly (6) from generator panel
(4).
(4)
Remove three wires (9) from main circuit
breaker (10).
(5)
Remove screw (11), lockwasher (12),
washer (13), ground wire (14) and insulator
(15) from generator control housing (16).
Push wires in generator control housing.
Discard lockwasher.
(6)
Remove four screws (17) and panel (18)
from generator control housing (16).