16
28
37
38
39
40
43
41
42
44
45
46
47
48
49
50
23
TM 9-4940-568-34
5-110
5-21. GENERATOR REPLACEMENT (CONT).
(14)
Remove wire T26 (37) from TB1 terminal
10 (38) on A11 card (28).
(15)
Remove wire (39) from TB1 terminal 8
(40) on A11 card (28).
(16)
Remove wire (41) from TB1 terminal 2
(42) on A11 card (28).
(17)
Remove wire (43) from terminal 30 (44) of
K33 ether start relay (23).
(18)
Remove wires P2 (45), P3 (46) and P4 (47)
from voltage regulator card (48) and pull
wires through back of generator control
housing (16).
(19)
Remove bottom black wire (xx-(F2)) (49)
and top black wire (x+-(F1)) (50) from
voltage regulator card (48) and pull wires
through back of generator control housing
(16).