TM 9-4940-568-34
3-85
c.
Adjustment
(1) Install cable follower (Para 3-22).
(2) Adjust nuts (13 and 14) to obtain a 0.19
.06 in. (.48 .15 cm) gap between
proximity sensor (12) and cable follower
(15).
END OF TASK
Follow-On Maintenance
Stow crane,
(TM 9-4940-568-10).
Check crane for proper
operation and hydraulic
leaks, (TM 9-4940-568-10).