TM 9-4940-568-10
3-48
3-6. BATTERY DISCONNECT/CONNECT (CONT).
b.
Connect.
5
2
4
1
6
8
10
7
8
9
7
3
2
1
NOTE
Install cable ties as required.
(1)
Install two terminals (8) on positive posts (9) and (10) on battery one (5) and battery two (6) and tighten
two nuts (7).
Terminal on battery post (3) must be installed after terminals on posts 4, 9 and 10 are
touched or battery damage or personnel injury may occur.
(2)
Install terminal (2) on negative post (4) on battery two (6) and tighten nut (1).
(3)
Install terminal (2) on negative post (3) on battery one (5) and tighten nut (1).
Corrosion inhibitor contains alkali. Do not get in eyes; wear goggles/safety glasses
when using. Avoid contact with skin. In case of contact, immediately wash area with
soap and water. If eyes are contacted, flush eyes with large amounts of water for at
least 15 minutes and get immediate medical attention.
(4)
Apply anticorrosion compound to positive posts (9) and (10) and negative posts (3) and (4) and terminals
(8) and (2).
c.
Follow-On Maintenance
Install panel (Para 3-8).
END OF TASK