TM 9-4940-568-10
3-51
This task covers:
a. Remove Panel
b. Stow Panel
INITIAL SETUP
3-8. GENERATOR SET PANEL REMOVAL/STOW.
Equipment Condition
FRS Unloaded, (Para 2-14)
a.
Remove Panel.
1
5
7
2
4
6
4
3
NOTE
If removing front panel or right rear panel, perform Steps (1) and (2).
If removing left rear panel, perform Steps (3) and (4).
If removing front panel from behind hydraulic tank, it may be necessary to move hydraulic
tank for clearance. Notify Unit Maintenance.
Two front panels and right rear panel are removed the same. Right rear panel shown.
(1)
Pull out handle (1), lift and remove panel (2) from two lower panel brackets (3) and generator set housing
(4).
(2)
Place panel (2) in a safe location.
(3)
Pull out handle (5) and lift panel (6) from upper panel bracket (7) and generator set housing (4).
(4)
Place panel (6) in a safe location.