2
1
TM 9-4940-568-10
3-46
This task covers:
a. Draining
INITIAL SETUP
Equipment Condition
FRS Unloaded, (Para 2-14)
Master Disconnect Switch OFF (Para 2-15)
3-5. AIR SYSTEM DRAINING.
a.
Draining.
During extreme cold weather (below 32F [0C]), air reservoir must be drained at end of
operation. Failure to comply may result in damge to equipment.
Air reservoir must be drained daily to prevent corrosion. Failure to comply may result in
damage to equipment.
(1)
To drain air from reservoir (1), turn air reservoir drain valve (2) clockwise until air is completely drained
from reservoir.
(2)
After air is completely drained from reservoir (1), turn air reservoir drain valve (2) counterclockwise
until closed.