TM 5-3805-296-23-6
0408
ASSEMBLY CONTINUED
CAUTION
Slide hammer rod must be clean before being used to move piston. Do not allow slide
hammer rod to contact sides of hydraulic accumulator. Failure to follow these cautions
may cause damage to equipment.
3. Using slide hammer rod (Figure 12, Item 3) to push piston (Figure 12, Item 1) to top of hydraulic accumulator
(Figure 12, Item 2).
4. Remove slide hammer rod (Figure 12, Item 3) from hydraulic accumulator (Figure 12, Item 2).
Figure 12. Slide Hammer Rod.
0408
5. Install weight (Figure 11, Item 3), plate (Figure 11, Item 4), nut (Figure 11, Item 2), and nut (Figure 11, Item 5)
on rod (Figure 11, Item 1).
6. Install new O-ring (Figure 13, Item 3) and fitting (Figure 13, Item 1) on hydraulic accumulator
(Figure 13, Item 2).
0408