Figure 7. Dust Cap.
Figure 9. Nitrogen Fitting.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  558    559    560    561    562  563  564    565    566    567    568  
img
.
TM 5-3805-296-23-6
0408
DISASSEMBLY CONTINUED
WARNING
Nitrogen gas is highly compressed. Wear eye protection. Use care when releasing
pressure. Do not point nitrogen gas discharge line at personnel. Failure to follow these
warnings may result in injury or death to personnel.
3. Disconnect air hose (Figure 8, Item 7) from valve (Figure 8, Item 6).
4. Close valve (Figure 8, Item 6) by turning handle (Figure 8, Item 1) clockwise until handle stops.
5. Close fitting (Figure 8, Item 5) by turning handle (Figure 8, Item 4) counterclockwise until handle stops.
6. Connect fitting (Figure 8, Item 5) to hydraulic accumulator fitting (Figure 8, Item 3).
7. Open fitting (Figure 8, Item 5) by turning handle (Figure 8, Item 4) clockwise until handle stops.
8. Slowly open valve (Figure 8, Item 6) by turning handle (Figure 8, Item 1) counterclockwise.
9. When gauge (Figure 8, Item 2) reads 0 psi (0 kPa) and no nitrogen is being released from valve
(Figure 8, Item 6), close valve by turning handle (Figure 8, Item 1) clockwise until handle stops.
10. Connect air hose (Figure 8, Item 7) to valve (Figure 8, Item 6).
11. Close fitting (Figure 8, Item 5) by turning handle (Figure 8, Item 4) counterclockwise until handle stops.
12. Disconnect fitting (Figure 8, Item 5) from hydraulic accumulator fitting (Figure 8, Item 3).
Figure 8. Nitrogen Discharge.
0408