TM 5-3805-296-23-6
0408
ASSEMBLY
000408
CAUTION
Hydraulic accumulator piston must be at top of hydraulic accumulator prior to charging
with nitrogen gas. Failure to follow this caution may cause damage to equipment.
1. If hydraulic accumulator piston (Figure 10, Item 2) is at bottom of hydraulic accumulator (Figure 10,
Item 1) or location can not be determined, proceed to step 2. If hydraulic accumulator piston is at top of
hydraulic accumulator, proceed to step 4.
Figure 10. Piston.